我正在尝试为 Model Predictive Control with the TCLab 修改 Python Gekko 中的示例代码使用二进制(开/关)代替 0 到 100% 之间的连续加热器值。我将选项切换为 integer=True 并将决策变量缩放为 0 到 1 而不是 0 到 100%,但它仍然为 Q1 提供连续值(非二进制)解决方案。

# Manipulated variables 
Q1b = m.MV(value=0,lb=0,ub=1,name='q1',integer=True) 
Q1b.STATUS = 1  # manipulated 
Q1b.FSTATUS = 0 # not measured 
Q1b.DMAX = 1.0 
Q1b.DCOST = 0.1 
Q1 = m.Intermediate(Q1b*100) 
 
Q2 = m.MV(value=0,name='q2') 
Q2.STATUS = 1  # manipulated 
Q2.FSTATUS = 0 # not measured 
Q2.DMAX = 30.0 
Q2.DCOST = 0.1 
Q2.UPPER = 100.0 
Q2.LOWER = 0.0 

当决策变量(操纵变量)必须是二进制或整数解时,如何使用 Gekko 进行最优控制?

请您参考如下方法:

您引用的示例问题使用默认的 IPOPT 求解器。要获得二进制或整数解,请切换到 APOPT 求解器。

m.options.SOLVER = 1 

您还需要做另一件事,因为您将 Q1 从 m.MV() 更改为 m.Intermediate 类型.在访问 Q1 值的循环中,进行以下修改:

Q1s[i+1]  = Q1.value[1] 
Q2s[i+1]  = Q2.NEWVAL 

Q2 仍然是 0 到 100% 之间的连续值,您仍然可以使用 Q2.NEWVAL 参数访问移动计划的第一步。对于 Q1,您需要使用 Q1.value[1] 访问第一步,因为它是一个 m.Intermediate()类型并且没有 NEWVAL 属性。该脚本使用 make_mp4=True 生成视频动画,如果安装了 ffmpeg。动画显示 Q1 现在是 ON/OFF(0 或 1)并且 Q2 仍然是 0 到 100% 之间的连续值。

二元变量模型预测控制

import numpy as np 
import time 
import matplotlib.pyplot as plt 
import random 
import json 
# get gekko package with: 
#   pip install gekko 
from gekko import GEKKO 
# get tclab package with: 
#   pip install tclab 
from tclab import TCLab 
 
# Connect to Arduino 
a = TCLab() 
 
# Make an MP4 animation? 
make_mp4 = False 
if make_mp4: 
    import imageio  # required to make animation 
    import os 
    try: 
        os.mkdir('./figures') 
    except: 
        pass 
 
# Final time 
tf = 10 # min 
# number of data points (every 3 seconds) 
n = tf * 10 + 1 
 
# Percent Heater (0-100%) 
Q1s = np.zeros(n) 
Q2s = np.zeros(n) 
 
# Temperatures (degC) 
T1m = a.T1 * np.ones(n) 
T2m = a.T2 * np.ones(n) 
# Temperature setpoints 
T1sp = T1m[0] * np.ones(n) 
T2sp = T2m[0] * np.ones(n) 
 
# Heater set point steps about every 150 sec 
T1sp[3:] = 40.0 
T2sp[20:] = 30.0 
T1sp[40:] = 32.0 
T2sp[60:] = 35.0 
T1sp[80:] = 45.0 
 
######################################################### 
# Initialize Model 
######################################################### 
# use remote=True for MacOS 
m = GEKKO(name='tclab-mpc',remote=False) 
 
# with a local server 
#m = GEKKO(name='tclab-mpc',server='http://127.0.0.1',remote=True) 
 
# Control horizon, non-uniform time steps 
m.time = [0,6,10,20,30,40,50,60] 
 
# Parameters from Estimation 
K1 = m.FV(value=0.607) 
K2 = m.FV(value=0.293) 
K3 = m.FV(value=0.24) 
tau12 = m.FV(value=192) 
tau3 = m.FV(value=15) 
 
# don't update parameters with optimizer 
K1.STATUS = 0 
K2.STATUS = 0 
K3.STATUS = 0 
tau12.STATUS = 0 
tau3.STATUS = 0 
 
# Manipulated variables 
Q1b = m.MV(value=0,lb=0,ub=1,name='q1',integer=True) 
Q1b.STATUS = 1  # manipulated 
Q1b.FSTATUS = 0 # not measured 
Q1b.DMAX = 1.0 
Q1b.DCOST = 0.1 
Q1 = m.Intermediate(Q1b*100) 
 
Q2 = m.MV(value=0,name='q2') 
Q2.STATUS = 1  # manipulated 
Q2.FSTATUS = 0 # not measured 
Q2.DMAX = 30.0 
Q2.DCOST = 0.1 
Q2.UPPER = 100.0 
Q2.LOWER = 0.0 
 
# State variables 
TH1 = m.SV(value=T1m[0]) 
TH2 = m.SV(value=T2m[0]) 
 
# Controlled variables 
TC1 = m.CV(value=T1m[0],name='tc1') 
TC1.STATUS = 1     # drive to set point 
TC1.FSTATUS = 1    # receive measurement 
TC1.TAU = 40       # response speed (time constant) 
TC1.TR_INIT = 1    # reference trajectory 
TC1.TR_OPEN = 0 
 
TC2 = m.CV(value=T2m[0],name='tc2') 
TC2.STATUS = 1     # drive to set point 
TC2.FSTATUS = 1    # receive measurement 
TC2.TAU = 0        # response speed (time constant) 
TC2.TR_INIT = 0    # dead-band 
TC2.TR_OPEN = 1 
 
Ta = m.Param(value=23.0) # degC 
 
# Heat transfer between two heaters 
DT = m.Intermediate(TH2-TH1) 
 
# Empirical correlations 
m.Equation(tau12 * TH1.dt() + (TH1-Ta) == K1*Q1 + K3*DT) 
m.Equation(tau12 * TH2.dt() + (TH2-Ta) == K2*Q2 - K3*DT) 
m.Equation(tau3 * TC1.dt()  + TC1 == TH1) 
m.Equation(tau3 * TC2.dt()  + TC2 == TH2) 
 
# Global Options 
m.options.IMODE   = 6 # MPC 
m.options.CV_TYPE = 1 # Objective type 
m.options.NODES   = 3 # Collocation nodes 
m.options.SOLVER  = 1 # IPOPT 
m.options.COLDSTART = 1 # COLDSTART on first cycle 
################################################################## 
# Create plot 
plt.figure(figsize=(10,7)) 
plt.ion() 
plt.show() 
 
# Main Loop 
start_time = time.time() 
prev_time = start_time 
tm = np.zeros(n) 
 
try: 
    for i in range(1,n-1): 
        # Sleep time 
        sleep_max = 6.0 
        sleep = sleep_max - (time.time() - prev_time) 
        if sleep>=0.01: 
            time.sleep(sleep-0.01) 
        else: 
            time.sleep(0.01) 
 
        # Record time and change in time 
        t = time.time() 
        dt = t - prev_time 
        prev_time = t 
        tm[i] = t - start_time 
 
        # Read temperatures in Celsius  
        T1m[i] = a.T1 
        T2m[i] = a.T2 
 
        # Insert measurements 
        TC1.MEAS = T1m[i] 
        TC2.MEAS = T2m[i] 
 
        # Adjust setpoints 
        db1 = 1.0 # dead-band 
        TC1.SPHI = T1sp[i] + db1 
        TC1.SPLO = T1sp[i] - db1 
 
        db2 = 0.2 
        TC2.SPHI = T2sp[i] + db2 
        TC2.SPLO = T2sp[i] - db2 
 
        # Adjust heaters with MPC 
        m.solve()  
 
        if m.options.APPSTATUS == 1: 
            # Retrieve new values 
            Q1s[i+1]  = Q1.value[1] 
            Q2s[i+1]  = Q2.NEWVAL 
            # get additional solution information 
            with open(m.path+'//results.json') as f: 
                results = json.load(f) 
        else: 
            # Solution failed 
            Q1s[i+1]  = 0.0 
            Q2s[i+1]  = 0.0 
 
        # Write new heater values (0-100) 
        a.Q1(Q1s[i]) 
        a.Q2(Q2s[i]) 
 
        # Plot 
        plt.clf() 
        ax=plt.subplot(3,1,1) 
        ax.grid() 
        plt.plot(tm[0:i+1],T1sp[0:i+1]+db1,'k-',\ 
                 label=r'$T_1$ target',linewidth=3) 
        plt.plot(tm[0:i+1],T1sp[0:i+1]-db1,'k-',\ 
                 label=None,linewidth=3) 
        plt.plot(tm[0:i+1],T1m[0:i+1],'r.',label=r'$T_1$ measured') 
        plt.plot(tm[i]+m.time,results['tc1.bcv'],'r-',\ 
                 label=r'$T_1$ predicted',linewidth=3) 
        plt.plot(tm[i]+m.time,results['tc1.tr_hi'],'k--',\ 
                 label=r'$T_1$ trajectory') 
        plt.plot(tm[i]+m.time,results['tc1.tr_lo'],'k--') 
        plt.ylabel('Temperature (degC)') 
        plt.legend(loc=2) 
        ax=plt.subplot(3,1,2) 
        ax.grid()         
        plt.plot(tm[0:i+1],T2sp[0:i+1]+db2,'k-',\ 
                 label=r'$T_2$ target',linewidth=3) 
        plt.plot(tm[0:i+1],T2sp[0:i+1]-db2,'k-',\ 
                 label=None,linewidth=3) 
        plt.plot(tm[0:i+1],T2m[0:i+1],'b.',label=r'$T_2$ measured') 
        plt.plot(tm[i]+m.time,results['tc2.bcv'],'b-',\ 
                 label=r'$T_2$ predict',linewidth=3) 
        plt.plot(tm[i]+m.time,results['tc2.tr_hi'],'k--',\ 
                 label=r'$T_2$ range') 
        plt.plot(tm[i]+m.time,results['tc2.tr_lo'],'k--') 
        plt.ylabel('Temperature (degC)') 
        plt.legend(loc=2) 
        ax=plt.subplot(3,1,3) 
        ax.grid() 
        plt.plot([tm[i],tm[i]],[0,100],'k-',\ 
                 label='Current Time',linewidth=1) 
        plt.plot(tm[0:i+1],Q1s[0:i+1],'r.-',\ 
                 label=r'$Q_1$ history',linewidth=2) 
        plt.plot(tm[i]+m.time,Q1.value,'r-',\ 
                 label=r'$Q_1$ plan',linewidth=3) 
        plt.plot(tm[0:i+1],Q2s[0:i+1],'b.-',\ 
                 label=r'$Q_2$ history',linewidth=2) 
        plt.plot(tm[i]+m.time,Q2.value,'b-', 
                 label=r'$Q_2$ plan',linewidth=3) 
        plt.plot(tm[i]+m.time[1],Q1.value[1],color='red',\ 
                 marker='.',markersize=15) 
        plt.plot(tm[i]+m.time[1],Q2.value[1],color='blue',\ 
                 marker='X',markersize=8) 
        plt.ylabel('Heaters') 
        plt.xlabel('Time (sec)') 
        plt.legend(loc=2) 
        plt.draw() 
        plt.pause(0.05) 
        if make_mp4: 
            filename='./figures/plot_'+str(i+10000)+'.png' 
            plt.savefig(filename) 
 
    # Turn off heaters and close connection 
    a.Q1(0) 
    a.Q2(0) 
    a.close() 
    # Save figure 
    plt.savefig('tclab_mpc.png') 
 
    # generate mp4 from png figures in batches of 350 
    if make_mp4: 
        images = [] 
        iset = 0 
        for i in range(1,n-1): 
            filename='./figures/plot_'+str(i+10000)+'.png' 
            images.append(imageio.imread(filename)) 
            if ((i+1)%350)==0: 
                imageio.mimsave('results_'+str(iset)+'.mp4', images) 
                iset += 1 
                images = [] 
        if images!=[]: 
            imageio.mimsave('results_'+str(iset)+'.mp4', images) 
 
# Allow user to end loop with Ctrl-C            
except KeyboardInterrupt: 
    # Turn off heaters and close connection 
    a.Q1(0) 
    a.Q2(0) 
    a.close() 
    print('Shutting down') 
    plt.savefig('tclab_mpc.png') 
 
# Make sure serial connection still closes when there's an error 
except:            
    # Disconnect from Arduino 
    a.Q1(0) 
    a.Q2(0) 
    a.close() 
    print('Error: Shutting down') 
    plt.savefig('tclab_mpc.png') 
    raise